Aurora is on version 2.5.0 C#, available at the Aurora Forums.
Contact Erik on the forum for a wiki account.
Difference between revisions of "Active Sensors/Fire Control"
(New Style) |
m (Corrected Formula) |
||
Line 8: | Line 8: | ||
An active sensor contact is necessary to open fire on a target. For smaller targets than the designed resolution the range is | An active sensor contact is necessary to open fire on a target. For smaller targets than the designed resolution the range is | ||
− | Max Range * Resolution | + | Max Range * Resolution Target^2 / Resolution Designed^2 |
Missile Fire Controls are designed like active sensors, but are unable to detect targets and are used to control missiles. | Missile Fire Controls are designed like active sensors, but are unable to detect targets and are used to control missiles. |
Revision as of 13:08, 25 August 2014
Description
An active sensor detects ships and missiles by their size.
An Active Sensor can detect ships at a range of
Sensor Stregth * Size * Sqrt[Resolution] * EM Sensitivity * 10,000km
An active sensor contact is necessary to open fire on a target. For smaller targets than the designed resolution the range is
Max Range * Resolution Target^2 / Resolution Designed^2
Missile Fire Controls are designed like active sensors, but are unable to detect targets and are used to control missiles.
Usage
Active Sensors are a necessity for any fleet. They are needed to target hostiles, and to detect incoming missiles. Design considerations are discussed in-depth here: Active Sensor Design
Missile Fire Controls can only operate in conjunction with an active search sensor. The active sensor does not have to be on the same ship.
Components
Active Grav Sensor Strength
Strength | 10 | 12 | 16 | 21 | 28 | 36 | 48 | 60 | 80 | 100 | 135 | 180 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
RP cost | 1,000 | 2,000 | 4,000 | 8,000 | 15,000 | 30,000 | 60,000 | 120,000 | 250,000 | 500,000 | 1,000,000 | 2,000,000 |
EM Sensor Sensitivity
Sensitivity | 5 | 6 | 8 | 11 | 14 | 18 | 24 | 32 | 40 | 50 | 60 | 75 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
RP cost | 1,000 | 2,000 | 4,000 | 8,000 | 15,000 | 30,000 | 60,000 | 120,000 | 250,000 | 500,000 | 1,000,000 | 2,000,000 |
Total Sensor Size
Total Sensor Size ranges between 0.1-50 HS.
Minimum Resolution
Minimum Resolution ranges between 1-500 HS.
Electronic Hardening
Hardening | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
---|---|---|---|---|---|---|---|---|---|
Chance of Destruction (%) | 100 | 70 | 50 | 40 | 30 | 25 | 20 | 15 | 10 |
RP cost | 1,000 | 2,500 | 5,000 | 10,000 | 20,000 | 40,000 | 75,000 | 150,000 | 300,000 |
Active Sensor Type
Type | Search Sensor | Missile Fire Control |
---|---|---|
Range Multiplier | 1 | 3 |
Use | Detection | Missile Guidance |
|